What wire size for what amperage?

For common circuits, the Code sets clear limits. Beyond that, the size depends on the metal, the insulation, the length and the installation: it is a calculation, not just reading a table.

What determines a wire's size

People often look for a single figure: this amperage, that size. The Code brings several elements into play at once. Manufacturers' data sheets show it well: their values refer to Rules 4-004 and 4-006 of the Canadian Electrical Code, to Table 2 for copper and Table 4 for aluminum, with a different column depending on the insulation's temperature rating.

Add to that the circuit protection, the length of the run and what you plan to plug in later. Reminder: on the AWG scale, the lower the number, the bigger the wire.

  • Current and protectionThe rating of the circuit's breaker or fuse.
  • The metalCopper or aluminum: two different tables in the Code.
  • The insulationIts temperature rating: 60, 75 or 90 °C.
  • The lengthA long run may call for a bigger wire.

14, 12, 10: the limits for common circuits

For the most common household circuits, in copper, Rule 14-104 of the Code sets the maximum protection allowed, regardless of the insulation's temperature rating and the number of strands:

  • 14 AWG copper wireProtection of 15 A at most.
  • 12 AWG copper wireProtection of 20 A at most.
  • 10 AWG copper wireProtection of 30 A at most.

Why some tables show more

On its data sheet for a copper cable, the manufacturer Southwire states that its values, taken from Table 2 of the Code (2024 edition), do not account for these 15, 20 and 30 A limits. A figure read in a table is therefore not, by itself, the breaker rating allowed.

What about aluminum?

The aluminum used in electrical wire conducts about 61% as well as copper at the same size. To carry the same current, an aluminum wire must therefore be bigger, and the Code does not allow aluminum thinner than 12 AWG.

The Code has its own table for aluminum, Table 4. Aluminum is still used today: manufacturers offer NMD90 cable in aluminum and ACWU90 armoured cable with 8000 series aluminum conductors, from 6 AWG to 750 kcmil.

Its connections require devices approved for it, marked Cu/Al or CO/ALR, and, on stranded conductors, a joint compound, unless the connector is approved for use without it.

Same number, two realities

An aluminum cable and a copper cable of the same gauge do not carry the same current. The jacket marking tells you the metal: it is the first thing the electrician looks at.

See the differences between copper and aluminum

Want to know for sure?Request your quote: same-day reply before 2 p.m., on weekdays.

Charger, heating, service: a circuit bigger than the appliance

For some appliances, the circuit must be bigger than the appliance's own current. For fixed heating, Quebec's building authority (RBQ) points out that, in the most common case, the minimum protection must be at least 125% of the load's rated current.

Our EV chargers give two concrete examples: charging at 32 A requires a 40 A circuit, and charging at 48 A, a 60 A circuit. The wire is then chosen for that circuit.

For an electrical service, the load calculation decides. Before upgrading to 200 A, we first check whether it is needed, with a written load calculation: it is not always the case.

  • Charger: 32 A charging on a 40 A circuit
  • Charger: 48 A charging on a 60 A circuit
  • 200 A service: written load calculation before the work

See EV chargers

See the 200 A electrical service

Length matters: voltage drop

A wire has resistance: the longer the run, the more voltage is lost along the way to the appliance. The Code governs this voltage drop in Rule 8-102.

The CMEQ even devotes a four-hour professional development course to this calculation alone, with three different methods; it covers in particular conductor resistance and the consequences of voltage drop. And Quebec's building authority (RBQ) notes that voltage drop, future needs or equipment availability can justify a wire with a much higher ampacity than the minimum.

When to plan biggerAccording to Quebec's building authority (RBQ).

  • A long run between the panel and the appliance
  • Appliances you plan to add
  • Equipment availability

Why it is the electrician's calculation

Choosing a wire size means combining several Code rules: the maximum protection for small gauges, the table for the metal, the temperature column, installation conditions and voltage drop. A single figure taken from a table is not enough.

In Quebec, the law also requires hiring an electrical contractor for this work. The price in your quote is firm, in writing, and valid for 30 days.

  • A master electrician, RBQ licence 5887-1153-01
  • A firm price, in writing, valid for 30 days
  • 2-year written warranty, parts and labour

Request a quote

Fill in these few fields: your request goes straight to our team. Add photos if you have them, of the panel, an outlet or a cable marking: they help us prepare your quote.

  • Same-day reply before 2 p.m. on weekdays
  • A firm price, in writing, valid for 30 days
  • No payment, no commitment

Would you rather talk to someone? 438 805-9862

Frequently asked questions

What wire size for 15 A?

In copper, 14 AWG is the smallest wire allowed, and the Code limits its protection to 15 A. The length of the circuit may call for bigger.

What wire size for 20 A?

In copper, the Code limits the protection of 12 AWG wire to 20 A. Depending on length and installation, the electrician may choose bigger.

What wire size for 30 A?

In copper, the Code limits the protection of 10 AWG wire to 30 A. For a long run, voltage drop may call for a bigger wire.

And for 40, 50 or 60 A?

There is no single answer: the metal, insulation, installation and length all matter. An example from us: a charger that charges at 48 A is on a 60 A circuit.

Why do some manufacturers' tables give more amps?

Because they do not account for the 15, 20 and 30 A limits that the Code sets for 14, 12 and 10 AWG copper wire, as the manufacturer Southwire states.

Can aluminum wire be used?

Yes. The Code has a table for it, and it must be bigger than copper for the same current, never smaller than 12 AWG, with devices marked Cu/Al or CO/ALR.

What size for a 200 A service?

The load calculation decides, and 200 A is not always needed. We check it first, in writing, before the work.

Can I do the calculation and wiring myself?

No: in Quebec, the law requires an electrical contractor. The calculation combines several Code rules, including voltage drop under Rule 8-102.