Your choice has an impact: 2% of our profits are given back. See how

Advice · Wiring and code upgrades

GFCI outlet : where is it required ?

Bathroom, hot tub, pool: a GFCI cuts the power as soon as current leaks to ground. Here is where Quebec's Safety Code requires one, even in an older home, with the section to back it up.

Does this outlet need protection?

Where is the outlet ?

Pick a location: the rule and its source appear here.

This tool sums up the rules published by the Government of Quebec and the Régie du bâtiment du Québec (RBQ). It does not replace an inspection: an electrician looks at where each outlet is, what already protects it and what the Code in force says for your work.

What a GFCI outlet does

GFCI stands for ground fault circuit interrupter (DDFT in French). The Office québécois de la langue française defines it as a device that automatically cuts power to a circuit when it detects a leak to ground. To spot it, the entry adds, it constantly calculates the difference between the incoming current and the ground current.

A leak is current heading to ground by a path other than the circuit's wires. The GFCI detects it and cuts the circuit. Ontario's Electrical Safety Authority (ESA) puts it its own way: a faulty GFCI increases the risk of electric shock.

It can sit in a GFCI outlet, which has its own test button, or at the start of the circuit.

The words

DDFT in French, GFCI in English in Canada : it's the same device. Quebec's texts speak of a “Class A ground fault circuit interrupter”.

A useful note if your inspection report flags ungrounded outlets: a GFCI at the start of the circuit protects people, but the outlet stays ungrounded. Replacing the cable with grounded copper fixes the problem at its source.

Even in an older home: the Safety Code

In electrical work, an installation is generally judged by the Code of its time. That's the grandfathering principle: what you don't modify doesn't have to follow every new Code.

Quebec's Safety Code, which applies to every electrical installation covered by the Building Act, including existing ones, sets a limit to that principle. Its section 10.1 says an installation must comply with the requirements that applied when it was built, “subject to the more stringent requirements” of the same chapter. And those more stringent requirements, in Division IV, start with the GFCI.

Section 22 of the Safety Code requires a Class A ground fault circuit interrupter in five cases, whatever the age of the home :

“ Subject to the more stringent requirements of this chapter, an electrical installation must comply with the regulatory requirements that applied when it was built. ” (our translation)

Safety Code, section 10.1 (up to date as of July 1, 2026)

  • BathroomThe outlet within 1.5 m of the bathtub or shower stall.
  • Hot tub and hydromassageHot tubs, whirlpools and hydromassage bathtubs.
  • In the poolElectrical equipment immersed in a pool's water.
  • Around the poolEquipment within 3 m of its walls, with no wall, partition or fence in between.
  • Speaker soundThe amplifier connected to speakers submerged in a pool.

In the bathroom, two outlets are exceptions: one combined with an isolating transformer, and the washing machine outlet, on the wall behind it, 600 mm or less from the floor.

The rule isn't new. Section 22 has existed since 2002; it was amended in 2018, for the bathroom, then in 2026, to specify “Class A” and replace “therapeutic bath” with “hot tub, whirlpool”.

Advice: grandfathered electrical installations

When work is done: the Construction Code

As soon as work is done, Chapter V, Electricity, of the Construction Code applies to the part affected. Since March 26, 2026, it has been based on the Canadian Electrical Code, 25th edition (CSA C22.1:21), with Quebec's own amendments.

The RBQ set a transition period: the previous version of the chapter can still be used if the work began before October 17, 2027.

For GFCIs, the 2026 Code covers, for example, the 120 V (5-20R) outlet used to charge a car: installed outdoors less than 2.5 m above finished ground, it must be protected by a Class A GFCI. For sinks, the RBQ reminded farm building owners in 2018 that outlets within 1.5 m of any sink or basin had to be, under the Code then in force.

What we don't quote

The full text of the Canadian Electrical Code is not free. Rules that don't appear in a public Quebec text, we check on site rather than quote from memory.

The 2026 Chapter V also contains circuit rules that affect outlets: at least one circuit for outdoor outlets easily reached from the ground, and at least one circuit reserved for the outlets of a house's garage or carport.

Want to know for sure?Request your quote: same-day reply before 2 p.m., on weekdays.

The other protection: arc-fault (AFCI)

The GFCI has a cousin: arc-fault protection, also called AFCI (DDFA in French). It targets electrical arcs in circuits. The RBQ explains that the Code requires it on many of the circuits that supply outlets in a dwelling; the 2026 Code keeps this protection, in rule 26-658.

It comes in two forms: a combination arc-fault breaker, right in the panel, or an arc-fault outlet, installed further along the circuit, under certain conditions.

A few circuits are exempt, according to the RBQ's training on the 2018 edition: outlets near sinks in bathrooms and washrooms, the circuit dedicated to the refrigerator, kitchen counter outlets, circuits that supply only outlets above 120 V, and the marked outlet of a sump pump.

  1. Old circuit without arc-faultYou want to add an outlet to it.
  2. First outlet addedAn arc-fault outlet: no need to protect the whole circuit.
  3. At most 10 outletsOn a circuit with arc-fault protection.

Test your GFCI outlet every month

A defective GFCI outlet can be spotted with its test button, ESA explains. It advises testing GFCI outlets every month, or as the manufacturer instructs.

The test uses the outlet's TEST button. If the power stays on after you press it, the GFCI is defective. According to ESA, defects are more common in older products.

A defective GFCI is replaced by an electrical contractor. In Quebec, the law reserves this work for an electrical contractor, whether or not you own the home.

  1. Press TESTEvery month, or as the manufacturer says.
  2. The power should cutThe GFCI is doing its job.
  3. Power stays on ?The GFCI is defective: have it replaced.

Have your outlets checked

Not sure whether your outlets are protected, or by what ? Our compliance inspection checks, among other things, outlet polarity and GFCI protection where required, with a signed report. It costs $499.99 plus taxes.

If you're renovating, our code upgrade installs the protections the Code requires, GFCI and AFCI, wherever it calls for them.

See the compliance inspection · See the code upgrade

In one sentence

Bathroom near the tub, hot tub, pool : a Class A GFCI, whatever the age of the home.

Request a quote

Fill in these few fields: your request goes straight to our team. Add photos if you have them, of the panel, an outlet or a cable marking: they help us prepare your quote.

  • Same-day reply before 2 p.m. on weekdays
  • A firm price, in writing, valid for 30 days
  • No payment, no commitment

Would you rather talk to someone? 438 805-9862

Frequently asked questions

Is a GFCI outlet required in a bathroom?

Yes, for the outlet within 1.5 m of the tub or shower: Quebec's Safety Code requires a Class A GFCI, even in an older home. Two exceptions: isolating transformer, washing machine outlet behind it.

Is my older home grandfathered for GFCIs?

Not for the bathroom, hot tub and pool. The Safety Code makes the GFCI a more stringent requirement, which applies whatever the age of the installation (sections 10.1 and 22).

What's the difference between DDFT and GFCI?

None: DDFT is the French term, GFCI the English term in Canada. Quebec's texts speak of a Class A ground fault circuit interrupter.

How do I test a GFCI outlet?

Press its TEST button: the power should cut. If it stays on, the GFCI is defective. ESA advises doing this test every month, or as the manufacturer says.

Does a GFCI replace grounding?

No. Installed at the start of an ungrounded circuit, it protects people, but the outlet stays ungrounded. Rewiring in copper fixes the cause.

GFCI or AFCI: which one for a bedroom?

When work is done, arc-fault protection (AFCI): the Code requires it on many of a dwelling's outlet circuits, the RBQ explains. The GFCI mainly targets places near water.

CallRequest a quote