Aluminum wiring · Pigtailing

Pigtailing aluminum wiring

We keep the aluminum wiring and redo every connection. $7,500 before taxes, up to 70 outlets.

  • Same-day reply before 2 p.m. on weekdays
  • No payment, no commitment

No time? Leave your number and we'll call you back.

By sending, you agree to be called back about your request. Privacy policy

In short

  • Aluminum wiring is not the problem: its connections are what heat up. We redo every connection, without replacing the wire.

  • The flat rate: $7,500 before taxes, up to 70 outlets. New outlets, switches and cover plates included.

  • Each connection gets a short copper wire, joined to the aluminum with a connector designed for both metals. COPALUM on request.

  • At the end: thermal imaging of the panel under load and a signed attestation, to give your insurer.

It is the connections that heat up

The aluminum wire stays in your walls. What changes is how it is connected to each outlet, each switch and each light fixture.

Before

Aluminum screwed on directly

Technical bulletin BTI-013 describes the failures seen at the time: loose connections in switches and outlets, caused by aluminum's expansion, cold creep and oxidation. It also notes poor installations: connections not tightened enough, wire wrapped the wrong way around the screw, outlets made for copper only.

After

A short copper wire to the device

We clean the aluminum and coat it with antioxidant paste, then join it to a copper pigtail. The copper is what goes to the new outlet or switch, screwed to a terminal made for it.

Advice: is aluminum wiring dangerous?

What technical bulletin BTI-013 says

Technical bulletin BTI-013, distributed by the CMEQ, « Jonction des conducteurs en aluminium » (3rd issue, February 2019, based on Chapter V, Electricity, 2018 edition), recalls a few dates.

  1. 1965 to 1974A large number of homes are wired with aluminum conductors, because copper is scarce and expensive.
  2. 1974Certification of push-in outlets for aluminum is withdrawn.
  3. 1975New standards take effect for outlets, switches and connectors used with aluminum: they carry the CO/ALR mark.
  4. 1974 to 1980Fewer homes get it: manufacturing of 12 and 10 gauge aluminum wire stops around 1975 or 1976.

« Aluminum conductors have never been prohibited by the Code. » Incidents were often caused by incorrect installation.

The bulletin also points out that aluminum is more fragile than copper: it must be installed with care, without nicking the wire when stripping the insulation.

Our method, outlet by outlet

For each outlet (receptacle, switch, light fixture), up to 70 outlets:

  1. We openOpening the box and inspecting the connections.
  2. We cleanCleaning the aluminum conductors and applying antioxidant paste.
  3. We connectA copper jumper, the “pigtail”, joined to the aluminum with a connector designed for both metals.
  4. We replaceNew outlet or switch, with a new cover plate.
  5. We checkClosing the box and checking.

A box that is too small

A box too small for the connection is enlarged or replaced.

Other defects

A defect found along the way, such as a damaged or overheated wire, is reported to you in writing with its price, before it is fixed.

Connector, COPALUM or CO/ALR outlet

Three ways of connecting aluminum. Here is the one we use, and why.

The Al/Cu connector

Our default method. A twist-on wire connector, the “marrette” as it is called in Québec, designed for copper and aluminum. Bulletin BTI-013 specifies that a twist-on connector used on aluminum must be CO/ALR approved, and that a device fitted only with pigtails can be connected this way.

The COPALUM connection

A copper connector crimped onto the aluminum with the manufacturer's tool. We install it when you or your insurer ask for it: send us their written request, and the quote reflects it.

The CO/ALR outlet

A 15 A outlet or switch that replaces a device on an aluminum circuit must carry the CO/ALR mark. With a pigtail, it is copper that reaches the device: the new outlet is made for copper.

The flat rate: $7,500 up to 70 outlets

A price before taxes, for a home with up to 70 outlets. The number of outlets is counted during the visit. Beyond 70, each additional outlet is presented and approved in writing before the work.

Anything added is covered by a written change order, approved before the work. Payment can be spread over 12 months interest-free, 50 % when the work is done, subject to eligibility.

Included in the flat rateNot included: replacing light fixtures, correcting other defects found, refinishing.

  • New outlets, switches and cover plates
  • Infrared thermal imaging of the panel under load, PDF report
  • Attestation for the insurer, signed by the master electrician
  • Declaration of work

An attestation that answers your insurer

  • Their written requestLetter, email or form: send us what your insurer wrote. The attestation then answers exactly what they ask for.
  • Thermal imagingThe panel is checked with a thermal camera while it is under load. The report is given to you as a PDF.
  • The signatureThe attestation is signed by Artémis's master electrician, a CMEQ member company (licence 5880-1457).

Repair or replace?

Pigtailing is right when the aluminum is in good condition and your insurer accepts it. If the wiring is damaged, or if you are renovating anyway, look at replacing it with copper instead.

We work in Lanoraie, Terrebonne, Mascouche, Repentigny, Lavaltrie, Joliette, Saint-Lin–Laurentides, Saint-Jérôme, Laval and Montreal.

  • Aluminum in good condition, insurer request: pigtailing
  • Damaged wiring or full renovation: replacement with copper
Send my photos

Compare the two solutions

Frequently asked questions

How much does pigtailing aluminum wiring cost?

$7,500 before taxes, up to 70 outlets. The number of outlets is counted during the visit. Beyond 70, each additional outlet is presented and approved in writing before the work.

What is a pigtail?

A short copper jumper. It is joined to the aluminum wire with a connector designed for both metals, then connected to the outlet or switch. So copper is what touches the device.

Is aluminum wiring banned in Québec?

No. Technical bulletin BTI-013, distributed by the CMEQ, says it clearly: aluminum conductors have never been banned. They require devices approved for aluminum and careful installation.

Can I install CO/ALR outlets myself?

This work belongs to an electrical contractor. A 15 A outlet connected directly to aluminum must carry the CO/ALR mark; a regular outlet, such as a standard Decora outlet, is usually approved for copper only.

How do you recognize an outlet made for aluminum?

By its marking. Since 1975, outlets, switches and connectors made for aluminum carry the CO/ALR mark, according to bulletin BTI-013, distributed by the CMEQ. Push-in outlets lost their certification for aluminum in 1974.

What is not included?

Replacing light fixtures, correcting other defects found and refinishing. A defect that is found is reported to you in writing, with its price, before it is fixed.

Can I pay in instalments?

Yes. Payment can be spread over 12 months interest-free, with 50% when the work is done, subject to eligibility.

What will I receive at the end of the work?

The thermal imaging report of the panel, as a PDF, and the attestation signed by the master electrician. The declaration of work is filed for you.

CallRequest a quote