Your choice has an impact: 2% of our profits are given back. See how
FR

Electrical code compliance inspection The real condition of your electrical installation, in writing.

A master electrician inspects your installation point by point. You get a signed report: what complies, what doesn't, and what to correct first.

$499.99 plus tax

Request an inspection

On-site visual inspection and signed report. Master electrician, CMEQ licence 5880-1457 and RBQ licence 5887-1153-01.

Two pages of a sample electrical compliance report: the list of points checked and the summary

When should you ask for an inspection?

  • Before buyingYou want to know what you are buying, beyond what the building inspector sees.
  • After a pre-purchase reportThe report flags electrical items. You want a master electrician's opinion.
  • At an insurer's requestYour insurer wants a picture of the installation before insuring or renewing.
  • Before a projectA renovation, an EV charger or a heat pump: you want to know if the installation can handle it.

What the inspection checks.

The inspection follows a written checklist, the same for every building. Each point gets a rating: compliant, non-compliant or not accessible.

Seen on our inspections

An electrical panel with no cover, surrounded by tangled cables, with a power bar hanging above it
Panel with no cover, bare wires, power bar hanging above
Close-up of old dusty breakers, with two conductors tightened under one screw
Two wires under one breaker screw
A spliced 1950s cable with its sheath damaged in several places enters a metal box
1950s cable, spliced, sheath damaged in several places

With the inspection, or after a charger installation

Infrared thermography of your electrical panel.

A thermal camera shows what the eye can’t see: heat. A loose or corroded connection runs hot. We scan your panel and its circuits while current is flowing, and we tell you where to look.

  • The panel and its circuitsWe scan the open panel breaker by breaker, along with the circuits that leave it.
  • Under loadThe scan is done while current is flowing: that is when poor connections heat up.
  • Hot spotsLoose or corroded connection, overheating breaker, overloaded or unbalanced circuit.
  • PDF report by emailA summary page with thermal images and photos, sent within 24 hours.

With a charger installation: $150 plus taxes ($350 value). For a stand-alone inspection or with another visit, the price is confirmed in writing before the visit.

Done by a master electrician certified as a Level 2 thermographer (ITC). For a charger, we do it once the charger is running: you see how your panel behaves under the new load.

The camera measures surface temperature at the time of the scan, under whatever load is present that day. It complements the visual inspection without replacing it, and it does not certify that the installation is compliant.

Request an inspection with thermographyPrice confirmed in writing before the visit.

What the inspection report contains.

You keep it. Your insurer, your buyer or your notary can read it.

  • Each point checked: compliant, non-compliant or not accessible
  • Photos of each non-compliance
  • The number of points checked and of non-compliances
  • The priority findings, in order of urgency
  • The recommended corrections, in stages
  • The master electrician's signature and licence number

How the inspection works, in three steps.

  1. 1You askYour request in two minutes, with the address and the reason for the inspection.
  2. 2We inspectA master electrician comes on site and follows the checklist, point by point.
  3. 3You get the reportSigned, with the photos, the priority findings and the recommended corrections.
Request an inspection438 805-9862

Payment plan, for all our contracts

A code-compliant installation, without paying it all at once.

  1. A firm price, in writingInstalments and dates in your quote.
  2. Half at the start of the work50% of the contract.
  3. The balance, month by monthOver 3, 12 or 24 months.
  • Under $6,0003 monthsInterest-free. Example: $3,600, that is $1,800 at the start of the work then 3 instalments of $600.
  • From $6,000 to $11,99912 monthsInterest-free. Example: $8,400, that is $4,200 at the start of the work then 12 instalments of $350.
  • $12,000 and over24 months3% annual interest. Example: $18,000, that is $9,000 at the start of the work then the $9,000 balance over 24 months.

Financing subject to eligibility: certain criteria apply and are checked with you before signing.

Request a quoteWritten agreement, signed before the work.

2% of our profits are given back. At payment, you choose to whom. See the three organizations

5,0★★★★★6 Google reviews · 5.0 on Soumission Rénovation
Professionnel. Travail bien fait. Cédric a apporté des solutions au problème de lumières dans notre cour.
Lise X · Outdoor lighting · Google review
Read the reviews

No time? Leave your number and we'll call you back.

By sending, you agree to be called back about your request. Privacy policy

See alsoWiring code upgradeElectrical service upgrade to 200 AHeating conversion to electric

Questions and details

What the inspection does not do.

Better to know beforehand.

  • It is a visual check of accessible components. We do not open walls and we do not remove any finishes.
  • What is not accessible on the day of the visit is marked “not accessible” in the report.
  • The report does not certify that the installation complies in every respect. It attests to what was seen and checked.
  • Corrections are not included. If you wish, we then give you a firm written price.

Frequently asked questions

How much does an electrical compliance inspection cost?

$499.99 plus tax. This price includes the on-site visit and the signed report.

Does the inspection replace a building inspector's?

No. The building inspector looks at the whole house. Our inspection covers only the electrical system, and it is done by a master electrician.

What happens if the report shows non-compliances?

The report ranks them by urgency and recommends corrections, in stages. If you wish, we give you a firm written price to do them. You remain free to entrust them to whomever you like.

Does the report guarantee that my installation is compliant?

No. It is a visual check of accessible components: we do not open walls. The report attests to what a master electrician saw and checked that day.

Why is thermography done under load?

A poor connection mostly heats up when current flows. With no load, the camera sees almost nothing. We record the load present during the scan in the report so the results can be read correctly.

CallRequest a quote