Advice · Aluminum wiring
Copper or aluminum: what sets them apart
Both metals carry current, but not in the same way. Conductivity, size, behaviour at connections: here are the differences that matter in a house.
Copper and aluminum, side by side
A wire's conductivity is measured in percent IACS: it is compared with that of reference annealed copper, set at 100%. The tables of the U.S. National Bureau of Standards, published in 1972 with the Aluminum Association, give 61% IACS for the aluminum used in wire (EC-H19 alloy), and 61.8% once annealed.
| Feature | Copper | Aluminum |
|---|---|---|
| Conductivity at the same size | 100% IACS (the reference) | 61% IACS (EC-H19) |
| Smallest wire allowed by the Code | 14 AWG | 12 AWG |
| Weight | Heavier | Lighter (2.703 g/cm³) |
| Oxidation | Slower | Easier; the oxide strongly resists current |
| Expansion with heat | Lower | High coefficient of expansion |
| Flexibility | More ductile | Breaks more easily if nicked or bent |
| Melting point | Higher | Lower |
Sources: NBS Handbook 109 (1972) for conductivity and density; bulletin BTI-013 distributed by the CMEQ (February 2019) for the rest.
Why aluminum has to be bigger
Aluminum conducts less well than copper at the same size: for the same current, it needs a larger cross-section. The Code also sets the smallest size allowed at 12 AWG for aluminum, compared with 14 AWG for copper. Reminder: on the AWG scale, a lower number means a thicker wire.
That is why the outlet and lighting circuits installed in aluminum between 1965 and 1980 are 12 or 10 gauge, the two sizes also named by the U.S. CPSC.
Key point
A cable marked “12 AWG · AL” does not compare with a copper cable of the same number: a wire's size is chosen according to its metal. That is the electrician's calculation.
Where the two metals meet
The Code requires avoiding direct contact between dissimilar metals. BTI-013 explains it: copper and aluminum in contact, in a damp or wet location, can cause galvanic action, which breaks down one of the two materials. In a connection or a device, this can make it defective.
Hence a simple rule: every outlet, switch or connector attached to aluminum must be approved for that metal and carry the Cu/Al or CO/ALR mark. An aluminum wire is never connected to a lug approved for copper only; adapters exist for that case. And large stranded aluminum wires require a joint compound, unless the connector is approved and marked for use without it.
A white terminal is not aluminum
A white-coloured terminal approved Cu/Al is made of an alloy compatible with both metals. That is precisely what lets it take either one.
Want to know for sure?Request your quote: same-day reply before 2 p.m., on weekdays.
Installing aluminum takes more care
Aluminum is less ductile than copper: one nick or bend too many, and it breaks. BTI-013 therefore requires stripping the insulation with great care, without damaging the conductor.
On a screw-terminal outlet or switch, the aluminum wire must make a three-quarter loop under the screw head, clockwise. The bulletin notes that this loop also improves copper connections, even though the Code does not require it for copper.
- Insulation stripped without nicksA nicked wire breaks more easily.
- 270° loop the right wayThree-quarters of a turn, clockwise.
- Devices marked for aluminumThey carry the CO/ALR or Cu/Al mark.
Why was aluminum installed?
Because of price. From 1965 to 1974, copper was scarce and expensive: many houses were wired with aluminum. Before that, the metal was reserved for a few large circuits, such as the range or the dryer.
The connection problems observed led to changes: new alloys, such as Alcan's Nual alloys, and, in 1975, new standards for outlets, switches and connectors, marked CO/ALR. Around 1975 or 1976, demand had dropped so much that 12 and 10 gauge aluminum wire was no longer made.
- Before 1965Aluminum on a few large circuits: dryer, range.
- 1965 to 1974Copper scarce and expensive: many houses in aluminum.
- 1975CO/ALR standards for outlets and switches.
- Around 1975-197612 and 10 gauge aluminum is no longer made.
Today, copper or aluminum?
The Code has never banned aluminum, and BTI-013 notes that more and more products are approved for both metals. For the ESA, in Ontario, it is safe as long as its connections are made properly.
In a house where the small circuits are still aluminum, the question becomes practical: keep the aluminum and redo every connection with approved devices, or rewire in copper. Nothing forces you to replace it: according to the RBQ, the Code is not retroactive as long as the installation is not modified.
- Keep the aluminum: pigtailing, $7,500 before taxes up to 70 outlets
- Switch to copper: rewiring, one room a day
Request a quote
Fill in these few fields: your request goes straight to our team. Add photos if you have them, of the panel, an outlet or a cable marking: they help us prepare your quote.
- Same-day reply before 2 p.m. on weekdays
- A firm price, in writing, valid for 30 days
- No payment, no commitment
Would you rather talk to someone? 438 805-9862
Frequently asked questions
What is the difference between copper and aluminum wiring?
At the same size, aluminum conducts about 61% as well as copper. It is lighter, oxidizes more easily, expands more and breaks more easily when bent.
Is copper better than aluminum?
It conducts better at the same size and its connections need less care. Aluminum, for its part, is lighter. Properly connected with approved devices, it is safe according to the ESA.
Can copper be connected to aluminum?
Yes, with devices approved for both metals, marked Cu/Al or CO/ALR, and by an electrical contractor. Never on a lug approved for copper only.
Why is aluminum wire bigger?
Because it conducts less well. The Code does not allow aluminum thinner than 12 gauge; for copper, the limit is 14 gauge.
What is percent IACS?
A metal's conductivity compared with that of reference annealed copper, which is 100%. The aluminum in electrical wire is 61% IACS.
Is aluminum wiring still allowed?
Yes. The Code has never banned it. Only the small 12 and 10 gauges stopped being made, around 1975 or 1976.
Why was aluminum installed in houses?
Because copper was scarce and expensive between 1965 and 1974. Many houses then got aluminum.
Do I have to replace my aluminum with copper?
Nothing requires it as long as the installation is not modified. You can have every connection redone, or have copper installed.
Sources
- National Bureau of Standards, Handbook 109, “Aluminum Wire Tables”, February 1972 (with The Aluminum Association)
- Technical installation bulletin BTI-013, « Jonction des conducteurs en aluminium », 3rd issue, February 2019 (distributed by the CMEQ, in French)
- U.S. Consumer Product Safety Commission (CPSC), “Repairing Aluminum Wiring”, publication 516
- Electrical Safety Authority (Ontario), “Aluminum Wiring”
- RBQ, « Mesures différentes et droits acquis » (published in Électricité Québec, April 2012, in French)