Is aluminum wiring dangerous?
The wire itself, no. Its connections, yes, if they were poorly made or have aged. Here is why, what the studies say, and the signs that call for a check.
The wire, or its connections?
The Code has never prohibited aluminum, and when there were incidents, it was often a matter of installation, notes BTI-013. Ontario agrees: for the ESA, this wire stays safe as long as every connection is made properly and the conductor is not damaged.
The weak point is where the aluminum wire meets a terminal, another wire or a connector. In the United States, the CPSC (the federal product safety agency) explains that several processes raise the resistance to current there. The connection then heats up when the circuit is in use, sometimes to a hazardous level, and the damage adds up each time.
- ExpansionAluminum expands more when it heats up: the connection loosens little by little.
- Cold creepUnder the pressure of a screw, the metal slowly flattens and the clamping force relaxes.
- OxidationAluminum oxidizes easily, and its oxide strongly resists current.
What do the studies say?
In the United States, a national survey by the Franklin Research Institute for the CPSC compared homes built before 1972. Those wired with aluminum were 55 times more likely to have at least one outlet connection reach “fire hazard conditions” than those wired with copper.
Read the scope of that figure carefully. The survey only covered outlet connections, not the other connections in the wiring. And no data was produced for aluminum-wired homes built after 1972.
In Canada, BTI-013 cites the report of Ontario's Commission of Inquiry on Aluminum Wiring, published in March 1979: only about 10% of fires were electrical, mostly because of appliances and extension cords, and very few started in the wiring, copper or aluminum.
“55 times more likely to have one or more outlet connections reach fire hazard conditions.”
CPSC, publication 516 (pre-1972 homes, outlet connections only)
Where are the weak points?
According to the CPSC, overheating happens at aluminum wire connections: outlets, switches, junction boxes, and also major appliances wired directly, such as the dishwasher or the furnace.
BTI-013 describes what was found at the time: loose connections in switches and outlets, poorly tightened connections, wires wrapped the wrong way around screws, and devices approved for copper only. It also mentions baseboard heaters that failed because standard twist-on connectors had been used.
Push-in outlets lost their approval for aluminum in 1974. Since 1975, outlets and switches designed for aluminum carry the CO/ALR mark.
Connections to checkEvery place an aluminum wire is connected matters.
- Outlets and switches
- Junction boxes and panel
- Baseboard heaters
- Permanently connected appliances
Want to know for sure?Request your quote: same-day reply before 2 p.m., on weekdays.
Warning signs to watch for
The CPSC and BTI-013 name similar signs. Each one is a reason to have the installation checked promptly, whatever metal the wires are:
- an outlet or switch plate that feels hot;
- flickering lights;
- a circuit that has stopped working;
- an unusual smell, like burning plastic, near an outlet or switch.
But the CPSC also notes that a failing aluminum connection is rarely noticeable, and that some have overheated without any warning at all. No sign is therefore no proof that all is well.
A sign? Don't touch it
Don't take anything apart: the CPSC points out the risk of electrocution, or of making things worse. It is an electrician's job.
Does a house with aluminum wiring pass inspection?
Nothing requires you to remove aluminum wiring. According to the RBQ, the Code does not apply retroactively: an existing installation is assessed by the rules in force when it was done, as long as it is not modified. A modified part, however, must follow the current Code.
When you buy, the building inspector reports what they see. Since October 1, 2024, Quebec's building authority (RBQ) has issued a certificate to these inspectors; it becomes mandatory on October 1, 2027. To fix the electrical system, you need an electrical contractor.
Insurers have their own rules. In Ontario, the ESA notes that some insurers will not cover an aluminum-wired home without an inspection. In Quebec, ask yours, in writing, what it requires for your house.
Code compliance inspection$499.99
Plus taxes. A master electrician comes on site and signs the report. It tells you what to fix first.
How to make the installation safe
BTI-013 is clear on the basic rule: any repair or replacement on an aluminum installation is done with devices approved for aluminum, marked CO/ALR or Cu/Al as applicable, twist-on connectors included, and according to the Code. In Quebec, this work is done by an electrical contractor.
There are two possible repairs. The first fixes every connection and keeps the wire in place. The second replaces the wiring with copper. The choice depends on your house, your budget and what your insurer asks for.
- Fix every connection: $7,500 flat rate before taxes, up to 70 outlets
- Replace with copper: one room a day, you stay home
- 2-year written warranty, parts and labour
Request a quote
Fill in these few fields: your request goes straight to our team. Add photos if you have them, of the panel, an outlet or a cable marking: they help us prepare your quote.
- Same-day reply before 2 p.m. on weekdays
- A firm price, in writing, valid for 30 days
- No payment, no commitment
Would you rather talk to someone? 438 805-9862
Frequently asked questions
Is aluminum wiring dangerous?
The wire itself, no: according to the ESA, it is safe if the connections are made properly. The risk comes from connections that loosen or oxidize, heat up, and deteriorate over time.
Why do aluminum connections heat up?
Aluminum expands more, slowly flattens under the screw (cold creep) and oxidizes easily. The connection loosens, resists current and heats up.
Is the risk really 55 times higher?
That is the result of a survey done for the CPSC in the United States, on outlet connections in pre-1972 homes. It covered neither the other connections nor newer homes.
Which signs should alert me?
Flickering lights, a plate that gets hot, a circuit that has stopped working or a burning smell near an outlet. But a connection can also fail with no sign at all.
Does a house with aluminum wiring pass inspection?
The wire is not banned and the Code is not retroactive. The inspector reports what they see; the insurer has its own rules. Ask it in writing what it requires.
Can I replace an outlet myself?
No: in Quebec, the law reserves this work for an electrical contractor. And a replacement outlet on aluminum must be marked CO/ALR: an ordinary Decora outlet is approved for copper only.
Should everything be replaced with copper?
Not necessarily. Fixing every connection while keeping the wire is the other way to go. Your house, your budget and your insurer guide the choice.
Does aluminum wiring cause many fires?
The 1979 Ontario report cited by BTI-013 notes that about 10% of fires were electrical, and that very few started in the wiring, copper or aluminum.
Sources
- U.S. Consumer Product Safety Commission (CPSC), “Repairing Aluminum Wiring”, publication 516
- Technical installation bulletin BTI-013, « Jonction des conducteurs en aluminium », 3rd issue, February 2019 (distributed by the CMEQ, in French)
- Electrical Safety Authority (Ontario), “Aluminum Wiring”
- RBQ, « Mesures différentes et droits acquis » (published in Électricité Québec, April 2012, in French)
- RBQ, « Faire inspecter une propriété » (residential building inspector certificate, in French)
- CMEQ, « Travaux d'électricité : faire le bon choix pour sa sécurité ! » (December 2020, in French)